  • Continuous lens power Smooth power changes in steps smaller than 0.25 D
  • Fast refraction Smart programs lead directly to the final prescription
  • Guided smart tests Algorithms adapt each test to the patient's answers
  • Better patient experience Silent lens changes and a wider field of vision

Overview

The Vision-R 700 is a digital phoropter for optometrists and ophthalmologists who want faster refraction without giving up accuracy. Its exclusive optical module provides silent, continuous changes in sphere and cylinder power, a technology called Digital Infinite Refraction. Patient-specific smart programs and algorithms guide each step, and the phoropter can also be used as a normal digital phoropter whenever you prefer full manual control.

Vision-R 700, view 2

Digital Infinite Refraction

In traditional refraction, sphere, cylinder and axis are bracketed one by one, even though each affects the others, so values must be rechecked. The Vision-R 700 compensates all three at the same time. Every patient answer is based on compensated powers, which leads more directly to the final result.

  • Continuous power: smooth, instant changes between dioptric powers, helping control accommodation
  • Smart algorithms use smaller and larger steps, then round to 0.25 D
  • Vertex distance is measured by cameras and compensated automatically
Vision-R 700: Digital Infinite Refraction

Easy to perform

Based on the imported patient data, the Vision-R 700 recommends the best smart program for each patient. Automated smart tests then change the test and calculate dioptric power in response to the patient’s answers. The guided procedure from start to finish gives an accurate result, even for less experienced operators. A help function explains the current test whenever you need it. The optional Easy Refraction Mode gives a fully guided refraction experience.

Vision-R 700: Easy to perform

Improved patient experience

The compact head and silent lens changes keep distractions to a minimum. Because lenses are not stacked as in a traditional phoropter, the patient enjoys a wider, more natural field of view without a tunnel effect. Patients can also answer “no difference” or “don’t know”, and the smart tests use those answers, so nobody feels they are failing a test. A final comparison step shows the new prescription on real-life scenes and charts, side by side with the old one.

Vision-R 700: Improved patient experience

Specifications

Centring

Interpupillary distance, far 49.0 to 80.0 (0.5 mm steps) mm
Interpupillary distance, near 55.0 to 83.0 (0.5 mm steps) mm
Adjustment Binocular and monocular
Convergence Automatic, from near target position and patient PD
Vertex distance 4.0 to 30.0 (0.1 mm steps), measured monocularly by cameras mm

Measuring range

Sphere -20.00 to +20.00 D
Cylinder Up to 8.00, depending on lens combination D
Steps Standard mode: 0.25 D adjustable; Intelligent mode: smaller and larger steps rounded to 0.25 D
Axis 0 to 180 (1° steps, adjustable) °
Prism 0 to 20 (0.1Δ steps, adjustable) Δ

Auxiliary lenses

Occluders and pinhole Dark occluders, pinhole
Retinoscopy and fog lenses +1.50 D, +2.00 D (optical module)
Jackson cross cylinders ±0.25 D, ±0.50 D (optical module)
Fixed cross cylinders ±0.50 D
Prisms 3Δ base up / down, 6Δ base up, 10Δ base in
Maddox rods Red, horizontal and vertical
Red/green filters Red on right eye, green on left eye
Polarised filter Linear and circular

Dimensions and weight

Phoropter head Width 29.6 cm top / 21.9 cm bottom, height 22.2 cm, depth 8.4 cm top / 6.5 cm bottom
Phoropter head weight 3.5 kg
Console Keyboard 28 x 22 cm, 10.4-inch screen, 3.0 kg
Power supply unit 16.3 x 19.3 x 5.8 cm, 1.0 kg

Downloads

FAQ

Frequently asked questions

Can’t find what you need? Our team is happy to help.

Ask a question

What is Digital Infinite Refraction?

It is the Vision-R 700’s optical module technology. It changes sphere and cylinder power continuously and compensates sphere, cylinder and axis at the same time, so the test reaches the final prescription more directly.

Do I have to use the smart programs?

No. The Vision-R 700 can also be used as a normal digital phoropter, giving you full control of the refraction.

How does the Vision-R 700 handle vertex distance?

Built-in cameras measure vertex distance from 4.0 to 30.0 mm, and the phoropter compensates automatically to the reference vertex distance.

Talk to us

Ask about the Vision-R 700

Tell us what you need: a quote, a demonstration in your practice, finance options or a brochure. Your regional representative will reply within one working day.

Enquiry
So the right representative can help you.

Your Essilor Instruments team

Speak to the representative for your province, or call the Johannesburg office on +27 87 365 2077.

Free State, Gauteng, North West, Limpopo, Mpumalanga

Ritchard Dry

Regional representative

082 802 2505
dryr@essilor.co.za

Northern Cape, Western Cape, Eastern Cape, KwaZulu-Natal

Stephan du Plessis

Regional representative

071 260 1408
duplesss@essilor.co.za

National

Marais Kotze

Instruments manager

082 929 7668
kotzem@essilor.co.za