Screening & Diagnostic

ATNC 550

Quiet, precise non-contact tonometry with corneal thickness correction

CE marked. For professional use only.

Enquire Book a demo Download brochure PDF Finance options
  • CCT corrected IOP IOP corrected automatically when central corneal thickness is entered
  • Soft air puff Quiet, gentle puff and short measurement time
  • Auto shoot Guided alignment, then the puff and measurement start automatically
  • Seated or standing Tilting, swivelling 5.7-inch screen for flexible operation

For eye care professionals

This page describes a medical device intended for use by qualified eye care professionals. Please confirm that you are a healthcare professional to continue.

Go to the home page

Overview

ATNC 550 is a quiet and precise non-contact tonometer for optometry practices that screen for glaucoma risk. It measures intraocular pressure with a soft air puff and corrects the IOP value for central corneal thickness, giving a more reliable figure to support the glaucoma decision-making process. A compact design and a screen that tilts and swivels let it fit into any consulting room or pre-test area, operated from either a seated or a standing position.

Essilor ATNC 550 non-contact tonometer with tilting screen

Accurate measurement

  • Automatic targeting: guided alignment shows when the eye is centred; once aligned the target turns green and the air pulse and measurement start automatically.
  • Automatic IOP correction: enter the central corneal thickness before or after the measurement and the IOP value is corrected automatically.
  • Reliability warning: an asterisk appears on screen when a reading is not reliable enough, so the operator knows to repeat it.

The measuring range is 1 to 60 mmHg, with a resolution of 1 mmHg.

ATNC 550: Accurate measurement

Comfort and ease of use

Measurement time is kept short to reduce patient stress, and the quiet, soft air puff makes the test more comfortable. A safety alarm sounds if the nozzle comes too close to the eye, to prevent contact. For the operator, a feather touch sensor button keeps control simple, and the 5.7-inch colour screen tilts up, down and sideways so it is easy to see while interacting with the patient. A built-in thermal printer and an RS-232C output handle results.

ATNC 550: Comfort and ease of use

Specifications

Intraocular pressure

Measuring range 1 to 60 mmHg (0.1 to 8.0 kPa); values below 7 mmHg are not guaranteed
Resolution 1 mmHg or 0.1 kPa
Accuracy ±5 mmHg or ±0.7 kPa
Working distance 11 mm
CCT compensation Yes, central corneal thickness entered before or after measurement

Adjustment range

Measuring unit, back and forth ±22 mm
Measuring unit, left and right ±43 mm
Measuring unit, up and down ±17 mm
Chinrest vertical adjustment ±30 mm

System

Monitor 5.7-inch colour LCD, tilting and swivelling
Printer Thermal, 58 mm paper width
Output RS-232C
Power supply 100 to 240 V, 50/60 Hz
Power saving 3, 5 or 10 minutes (selectable)
Dimensions (W x H x D) 240 x 430 x 422 mm
Weight Approx. 13 kg

Downloads

Works with

WAM 800

Wavefront & topography

WAM 800

Fully automatic anterior segment screening with up to 9 measurements in about 2 minutes

Cornea 550+New

Wavefront & topography

Cornea 550+

Multifunctional corneal topographer for contact lens fitting and dry eye assessment

FAQ

Frequently asked questions

Can’t find what you need? Our team is happy to help.

Ask a question

Why correct IOP for corneal thickness?

Corneal thickness affects the pressure reading. ATNC 550 adjusts the IOP value automatically once the central corneal thickness is entered.

Is the air puff uncomfortable?

ATNC 550 uses a quiet, soft air puff and a short measurement time to keep the test as comfortable as possible.

Can it be used standing up?

Yes. It can be operated seated or standing, and the screen tilts and swivels to suit.

Talk to us

Ask about the ATNC 550

Tell us what you need: a quote, a demonstration in your practice, finance options or a brochure. Your regional representative will reply within one working day.

Enquiry
So the right representative can help you.

Your Essilor Instruments team

Speak to the representative for your province, or call the Johannesburg office on +27 861 486 100.

Free State, Gauteng, North West, Limpopo, Mpumalanga

Ritchard Dry

Regional representative

082 802 2505
dryr@essilor.co.za

Northern Cape, Western Cape, Eastern Cape, KwaZulu-Natal

Stephan du Plessis

Regional representative

071 260 1408
duplesss@essilor.co.za

National

Marais Kotze

Instruments manager

082 929 7668
kotzem@essilor.co.za