Wavefront & topography
WAM 800
Fully automatic anterior segment screening with up to 9 measurements in about 2 minutes
Quiet, precise non-contact tonometry with corneal thickness correction
CE marked. For professional use only.
ATNC 550 is a quiet and precise non-contact tonometer for optometry practices that screen for glaucoma risk. It measures intraocular pressure with a soft air puff and corrects the IOP value for central corneal thickness, giving a more reliable figure to support the glaucoma decision-making process. A compact design and a screen that tilts and swivels let it fit into any consulting room or pre-test area, operated from either a seated or a standing position.
The measuring range is 1 to 60 mmHg, with a resolution of 1 mmHg.
Measurement time is kept short to reduce patient stress, and the quiet, soft air puff makes the test more comfortable. A safety alarm sounds if the nozzle comes too close to the eye, to prevent contact. For the operator, a feather touch sensor button keeps control simple, and the 5.7-inch colour screen tilts up, down and sideways so it is easy to see while interacting with the patient. A built-in thermal printer and an RS-232C output handle results.
| Measuring range | 1 to 60 mmHg (0.1 to 8.0 kPa); values below 7 mmHg are not guaranteed |
|---|---|
| Resolution | 1 mmHg or 0.1 kPa |
| Accuracy | ±5 mmHg or ±0.7 kPa |
| Working distance | 11 mm |
| CCT compensation | Yes, central corneal thickness entered before or after measurement |
| Measuring unit, back and forth | ±22 mm |
|---|---|
| Measuring unit, left and right | ±43 mm |
| Measuring unit, up and down | ±17 mm |
| Chinrest vertical adjustment | ±30 mm |
| Monitor | 5.7-inch colour LCD, tilting and swivelling |
|---|---|
| Printer | Thermal, 58 mm paper width |
| Output | RS-232C |
| Power supply | 100 to 240 V, 50/60 Hz |
| Power saving | 3, 5 or 10 minutes (selectable) |
| Dimensions (W x H x D) | 240 x 430 x 422 mm |
| Weight | Approx. 13 kg |

Wavefront & topography
Fully automatic anterior segment screening with up to 9 measurements in about 2 minutes
NewWavefront & topography
Multifunctional corneal topographer for contact lens fitting and dry eye assessment
Corneal thickness affects the pressure reading. ATNC 550 adjusts the IOP value automatically once the central corneal thickness is entered.
ATNC 550 uses a quiet, soft air puff and a short measurement time to keep the test as comfortable as possible.
Yes. It can be operated seated or standing, and the screen tilts and swivels to suit.
Talk to us
Tell us what you need: a quote, a demonstration in your practice, finance options or a brochure. Your regional representative will reply within one working day.
Speak to the representative for your province, or call the Johannesburg office on +27 861 486 100.
Free State, Gauteng, North West, Limpopo, Mpumalanga
Regional representative
Northern Cape, Western Cape, Eastern Cape, KwaZulu-Natal
Regional representative